Enter the Capture Screen

Tap GO to enter the standby-for-scanning screen.

The device is time-calibrated at the factory, but long storage may cause the time to drift. LixelGO enables automatic synchronization by default, syncing the phone's time to the device. You can also set the device time manually in LixelGO; set the device time and time zone to match your actual location to keep the data records accurate.

Standby-for-scanning screen
Time synchronization setting
Set the device time manually
Time zone setting

Scan Mode Settings

Tap the red Record button on the right side of the screen. The real-time algorithm adaptively maps the scene. Select the following settings based on your situation.

Mount Type

ModeFunctionDescription
HandheldCapture in handheld modeLixelStudio automatically reads the mount type, so no manual selection is needed during project processing

GNSS Mode

ModeFunctionDescription
RTKUses the RTK module's RTK function to receive differential data for real-time positioning and records it in the project fileSelect RTK mode on the startup page; use the RTK module for project processing in LixelStudio
PPKUses the RTK module's PPK function to receive raw satellite data and records it in the project fileSelect PPK mode on the startup page; use the PPK module for project processing in LixelStudio

Scan Mode

ModeFunctionSupported Rendering Modes
Guided ModeEvaluates scan quality in real time to help assess coverageSupports Scan Assist System and Scan Quality rendering; does not support true-color point cloud rendering
RGB ModeView the real-time true-color point cloudSupports true-color rendering; does not support Scan Assist System or Scan Quality rendering
Scan mode settings screen

Project Naming

When you start a scan, the startup page shows a project name input field that supports multiple languages.

  • If you enter "Parking Lot B2F" and start scanning, then enable USB mode after the scan, the project folder is named Parking_Lot_B2F_2025-01-15-1622026, with the scan time as the suffix.
  • If no project name is entered, the folder is named default_2025-01-15-1622026.

Start Scanning

Static Initialization (Required)

After selecting the scan mode, the device automatically starts the LiDAR:

  1. Watch the indicator light: fast-flashing green means the LiDAR has started; the app prompts "Static initialization started".
  2. Stay still for 15 seconds: do not move the device; keep it stable. The screen shows a countdown; wait for the pop-up "Static initialization complete".
  3. Start scanning: close the pop-up, pick up the device, and start scanning along the planned route.
Static initialization started
Initialization countdown
Initialization complete

Handheld Posture Suggestions

  • Goal: reduce how much of the operator appears in the camera's field of view to improve colorization.
  • Recommended: hold the device extended in front of your chest.
  • Avoid: keeping the device close against your body.

Scan Route Suggestions

Lighting

  • Choose an environment with suitable lighting.
  • Avoid strong light/dark contrast.

Field of view

  • Prefer routes with a wide field of view (such as the middle of a road) to improve color point cloud coverage and colorization accuracy.

Special case: narrow-space scanning (gaps between buildings, alleys, etc.)

  • Slow down, moving more slowly than normal walking.
  • Scan when there are no people or moving objects nearby.
  • Ensure accurate point cloud data and good colorization.

Rendering Mode

Tap the Rendering Mode button on the left side of the screen to choose a display option:

ModeDescription
EL ElevationColors the point cloud by height, making terrain relief easy to see
RGB True colorDisplays the point cloud in true color, making objects easy to identify
QUAL Scan qualityDisplays point cloud density in real time to help assess coverage

About Scan Quality display

  • Purpose: check whether point cloud density is sufficient, avoiding missed areas or rework from sparse coverage.
  • Note: it does not represent scan accuracy, nor does it reflect LCC scan quality.

We recommend switching to QUAL mode periodically during scanning to check coverage and ensure no areas are missed.

Rendering mode display

Scan Assist System

Purpose

  • Check whether point cloud density is sufficient.
  • Avoid missed areas or rework from sparse coverage.

Note

  • It does not represent scan accuracy, nor does it reflect LCC scan quality.

How to use

  1. After starting a scan, tap Scan Assist System below the stop button.
  2. The system starts and enters the settings screen.
  3. Adjust the step distance based on your situation.
Scan Assist System entry: below the stop button
System started
Guidance screen
Follow the guidance
Scan result display
Step distance setting

Stop Scanning

  1. Tap the red End Recording button on the right side of the screen.
  2. Confirm to stop scanning in the pop-up.
  3. Watch the indicator light:

    • Fast-flashing green: data is being saved.
    • Solid green: scanning is complete and data is saved.
  4. When done, you can power off the device or start another scan.
Tap End Recording
Confirm stop scanning

View Model

After scanning, you can view model information, take measurements, and share offline through LixelGO.

View model information

Home screen
Model list
Model details
Model preview
Model operations
Viewing angle

Measurement

In model view, you can perform distance (line) and area measurements.

Measurement demo 1
Measurement demo 2
Measurement demo 3

Offline Sharing

The LixelGO Offline Preview module lets you quickly share models. The share format is .las.

Offline preview entry
Offline preview screen
Share options

Downloading Scan Data

Steps

  1. Enable USB mode: after powering on, set the device to USB mode in LixelGO.
  2. Connect to a computer: use a Type-C cable to connect the device to the computer.
  3. Copy project files: open the device's USB directory, go to the model folder, select the corresponding project file, and copy it to a suitable directory on the computer.

Project file naming rule

The file name format is ProjectName_year-month-day-time, for example:

  • Parking_Lot_B2F_2025-01-15-162026
  • default_2025-01-15-143520
Copy project files to the computer

Data Project File Structure

The project file structure is as follows:

Project file directory structure
File / DirectorySubfileDescription
xxx.xbin—Raw sensor data recorded by the device
map.las—Point cloud output by the device in real time
project_datacontrol_points.csvControl point information recorded when adding control points in LixelGO
gnss.csvGNSS information recorded when using RTK
poses.csvTrajectory file recorded during scanning
project.jsonDevice attributes and related information
modelIn-app model preview file
photoCamera image captured when adding a control point
preview_photo.jpgProject preview image
logLog recorded during scanning
external_data—Empty initially; used to store external data required for LixelStudio post-processing

This chapter is from the official XGRIDS user manual. Official source (opens in a new tab) · Updated:

XGRIDS Türkiye

We're With You During Setup and in the Field

Atlıhan Harita provides training and technical support for device setup, firmware updates, software use, and field applications. Send us your question and our specialist will get back to you.

+90 216 546 0804