Skip to content
TREN
Atlıhan Harita

Lixel OpenAPI User Manual

Project File Access

Chapter 06 / 09Manual version v1.1.0English

A Lixel device exposes project files in two ways:

  • HTTP: the interface responses give file URLs directly; read them with a browser or HTTP client, no file sharing needed.
  • File sharing (SMB): mount the device with a standard file-sharing client; must be enabled first.

Reading project files over HTTP

In the responses of project_list (AC_LIST_ALL_PROJECTS) and modeling_status, fields such as poses_url, control_points_url, measure_points_url, and xbin_url are HTTP URLs of the form http://<host>/static/<project>/project_data/poses.csv; for projects on external storage the path uses /udisk/.

The host in the URL is taken from the device's wireless interface address, falling back to 192.168.55.1 when unavailable (192.168.144.100 on the F1 model, per the device-side source). Over a wired connection it may be 192.168.56.1, which the host cannot reach. Measured on a Lixel L2Pro (firmware V3.2.1): over a wired connection the host returned by project_list was 192.168.56.1 and timed out; replacing the host with 192.168.55.1 returned HTTP 200. So over a wired connection, replace the host in the URL with the same address you use for MQTT before accessing it.

Enabling file sharing

The file-sharing service is off by default. Before access, send the enable action through the device control interface:

  • Enable: action: AC_START_FS
  • Disable: action: AC_STOP_FS

For the device control interface, see Interface Catalog · Device Management.

Warning: file sharing uses a fixed default credential. Anyone who knows it and can reach the device's network can access the files. Enable it only when needed and send AC_STOP_FS when done.

Connection parameters

Once enabled, mount with these parameters:

ParameterValueNote
Service addresssmb://<device_ip>/sharedevice_ip matches the MQTT connection address
UsernameadminDefault, not changeable
Passwordadmin123Default, not changeable

Note: device_ip is the same address you use for the MQTT connection (192.168.55.1 wired, or the Wi-Fi address obtained over Bluetooth for wireless).

This chapter is from the official XGRIDS user manual. Official source (opens in a new tab) · Updated:

XGRIDS Türkiye

We're With You During Setup and in the Field

Atlıhan Harita provides training and technical support for device setup, firmware updates, software use, and field applications. Send us your question and our specialist will get back to you.

+90 216 546 0804